Products >
PROMARINE®-450
> Applications >
Fire Protection >
Ceiling >
Ceiling Installation Instruction |
|
 |
|
|
 |
|
|
| |
B15 Standard Ceilings
This instruction is based on the B15 standard ceiling,
using 16mm thick PROMARINE®-450 and laminated on both sides with 0.8mm thick HPL (high pressure laminate)
Maximum board dimension is 2430mm x 1210mm.
Prior to the installation of PROMARINE®-450 laminated
B15 ceiling and the ordering of the materials, the orientation of
the ceiling grid must be decided. Consultation with the Promat
Marine Department prior to this decision is recommended. |
|
| |
Detail C Main channels
|
|
 |
|
|
| |
|
|
| |
 |
The main
channels (PJ-40-U) are supported
between the ceiling perimeter
channels and the adjustable hanger
assemblies using 3-way (CB-03-40)
and/or 4-way connector joints
(CB-04-40) together with the hanger
bracket as shown.
|
|
Centre main channels
should be installed first. After cutting to
the required length, connector joints should
be attached at either end. This is achieved
by folding the upright legs onto the
channels.
|
|
The main channels are
then loosely fitted to the adjustable hanger
assembly using M6 bolt provided. Each end of
the channel can now be secured to the
ceiling perimeter channel and/or other main
channels as required, using the same process
as prescribed.
|
|
If the span is longer
than 2500mm, two main channels can be joined
together with a CB-02-40 straight connector,
again, the upright legs are simply folded
into position..
|
|
|
|
|
| |
Ceiling Profiles
(click here to see the
details)
CB-02-40
CB-03-40
CB-04-40
Detail A
Detail B Detail C
Detail D
Detail E
Detail F |
Length |
Not applicable |
Thickness |
0.80mm |
Weight |
0.074kg each |
Finish |
Zintec |
Note : Ensure the tabs are tightly
crimped into position over each
section. |
|
Length |
Not
applicable
|
Thickness |
0.80mm |
Weight |
0.038kg
each |
Finish |
Zintec |
Note : Ensure the tabs are tightly
crimped into position over each
section.
|
|
Length |
Not applicable |
Thickness |
0.80mm |
Weight |
0.076kg
each |
Finish |
Zintec |
Note : Ensure the tabs are tightly
crimped into position over each
section.
|
|
|
|