Perimeter Omega
(PJ-23-W)
Large Omega
(RJ-28-W)
PROMARINE®-640 boards 16mm thick of ≤
2440mm x 610mm at density ≤ 640kg/m³ +/-10%
 
Ceiling perimeter channel(PC-25-T)
PROMARINE®-640 cover fillet minimum 12mm thick
CB-2 Ceiling Single Cross Connector

CB-1 Ceiling Double Cross Connector

PC-27-U Ceiling Channel

25mm x 1.6mm mild steel hanger welded to steel deck and support channel
Ceiling panel
Steel deck
Mineral wool 50mm thick insulation
(for A60 standard construction only)
PROMARINE®-640 board 21mm thick screwed to angle hangers
Steel angle hangers 20mm x 20mm x 1.5mm at
600mm centres welded to deckhead and bulkhead top section
Top section ceiling support (PJ-31-P)



Typical panel arrangement

Detail A
 

 

Below are the bulkheads profiles for Detail A, B, and Detail C.

Click on the blue bullet in each drawing to see the relevant profile.

Detail A uses PC-25-T and RJ-28-S

Detail B uses PC-25-T, RJ-28-S, CB1, CB2, PC-27-U, and PJ-23-S

Detail C uses PC-25-T, PJ-23-S, and PC-17-G

 



Details of ceiling construction

Detail B
 

 
 



B0 or B15 bulkhead connection to deckhead showing fill-in piece

Detail C

 
 