email home
Products > PROMARINE®-640 > Applications > Fire Protection > Ceilings  
   
 

Fire Protection Ceilings

Class C

Materials for construction of Class ceilings must be approved for non-combustibility.
   
Methods of installation -- no mandatory requirements, except that support profiles etc. must be made of steel or similar non-combustible material.
 
 

 
 
 

If ordering pre-bonded PROMARINE®-640 panels use minimum 9.5mm PROMARINE®-640 bonded with 0.9mm thick decorative laminate one side, balancer on reverse.

Minimum thickness of PROMARINE®-640 for C Class ceiling construction is 9.5mm

Minimum total panel thickness 11.5mm nominal

Weight is 8.5kg per square metre


 
 Class B0
 
If ordering pre-bonded panels use minimum 9.5mm PROMARINE®-640 bonded with 0.9mm thick decorative laminate one side, balancer on reverse.

Minimum thickness for B0 ceilings is 9.5mm  PROMARINE®-640

Minimum total panel thickness 11.5mm nominal

Weight is 8.5kg per square metre


Panels are approved for installation in size 2400mm x 1200mm which can substantially reduce the number of support profiles required.
 
Drawings and approved methods of construction can be found HERE
 

 Class B15
 

If ordering pre-bonded panels use minimum 15.9mm PROMARINE®-640 bonded with 0.9mm thick decorative laminate one side, balancer on reverse.

Minimum thickness for B15 ceilings is 15.9mm  PROMARINE®-640

Minimum total panel thickness 18mm nominal

Weight is 12.6kg per square metre


Panels are approved for installation in size 2400mm x 600mm which can substantially reduce the number of support profiles required.
 
Drawings and approved methods of construction can be found HERE
 
 
Class A0 ~ A15

 
As per above Class B0
 

Class A30

 
As per above Class B15
 

Class A60

 
As per above Class B0
 
 
  Click here approval and installation for Class A  Steel Divisions
See also approval and installation for Construction of Class B0, B15, A15, A30, & A60
 
 
 